Operating range: up to 50 Kw
Discharge line:
- Thermometer;
- Check excludable valve
- Air separator with manual vent valve
Line Return:
- Flow regulator measuring (8-28 l/min) with valves for loading and unloading facility
- High efficiency solar circulating pump gland mod. Wilo Yonos Para ST 25/7 PWM2 (Absorbed power 3-70 W)
- Flanged ball valve with 3-way non-return valve 10 mbar (the non-return valve can be excluded by rotating the handle by 45°) provided with door handle thermometer (thermometer with blue ring 0° C-120° C)
- Security unit 6 bar with manometer diam. 50 mm 0-10 bar with ¾“ male for expansion vessel.
Solar control unit complete with pre-wired sensors for monitoring temperature differential for standard solar system with 1 collector and 1 accumulator. Bright display with high contrast and backlit pictograms representative for hydraulic diagrams available.
- 4 inputs for temperature probes PT1000
- 2 output relays (230 V)
- 1 PWM/0-10 V output for the management of one high efficiency circulator
- External connection via CAN-Bus or Ethernet
- Complete with 2 temperature sensors PT 1000 silicone
Continuous temperature 120° C (short term up to 160° C for 20s)
External connections: 1“ Male-wheelbase 125 mm.
Box EPP insulation